Designing and production of power cable accessories, joints and terminations, has been the
specialty
of our company since 1981. Elcon Megarad focuses on customer-made designs to meet specific requirements
based on material, installation procedures, specifications and standards.
ELCOTERM GLM --63/E
Heat shrinkable medium voltage (max 36 kV) transition joint between a three core, separated lead sheaths, radial electric field, paper insulated cable and three single core XLPE or EPR insulated cables. Copper or
aluminum conductors. Cable connectors are not included.
ELCOTERM GLM --66/E
Heat shrinkable medium voltage transition joint between either a three core - lead sheathed and belted- non radial electric field - paper insulated cable (max 17.5 kV) or a three core - lead sheated - each core shielded, radial electric field - paper insulated cable (max 36 kV) and three single core XLPE or EPR insulated cables. Copper or
aluminum conductors. Cable connectors are not included.
ELCOTERM GLM --75/EZ
Heat shrinkable medium voltage transition joint between either a three core - lead sheathed and belted - non radial electric field - paper insulated cable (max 17.5 kV) or a three core - lead sheathed - each core shielded, radial electric field - paper insulated cable (max 36 kV) and a three core XLPE insulated, wire or tape screened,
armored cable. Copper or aluminum conductors. Steel canister included for cable
amour restore. Cable connectors are not included.
ELCOTERM GLM --76/EZ
Heat shrinkable medium voltage (max 36 kV) transition joint between a three core, separated lead sheath, radial electric field, paper insulated cable and a three core XLPE insulated, wire or tape screened,
armored cable. Copper or aluminum conductors. Steel canister included for cable
amour restore. Cable connectors are not included.
ELCOTERM GLT --65/E
Heat shrinkable medium voltage (max 36 kV) transition joint between a three core,
armored, XLPE insulated cable, and three single core XLPE insulated cables. Copper or
aluminum conductors. Wire or tape screened. Cable connectors are not included.
ELCOTERM TIS --82/E
Heat shrinkable medium voltage (max 36 kV) indoor termination for single core, EPR or XLPE insulated, wire or tape screened cable, without
amour*. Copper or aluminum conductor. Three terminations per kit. Cable lug not included.
ELCOTERM TIS --82/TZ
Heat shrinkable medium voltage (max 36 kV) indoor termination for three core, EPR or XLPE insulated, wire or tape screened,
armored or not armored cable. Copper or aluminum conductors. Cable lugs not included.
ELCOTERM TES --84/E
Heat shrinkable medium voltage (max 36 kV) outdoor termination for single core, EPR or XLPE insulated, wire or tape screened cable, without
amour*. Copper or aluminum conductors. One termination per kit. Cable lug not included.
ELCOTERM TES --84/TZ
Heat shrinkable medium voltage (max 36 kV) outdoor termination for three core, EPR or XLPE insulated, wire or tape screened,
armored or not armored cable. Copper or aluminum conductors. Cable lugs not included.
ELCOTERM TIC --56/E
Heat shrinkable medium voltage indoor termination either for three core - lead sheathed - individual screen - radial electric field- paper insulated cable (max 36 kV), or for three core - lead sheathed and belted - non radial electric field - paper insulated cable (max 17.5 kV). Cables
armored or not armored. Copper or aluminum conductors. Provided with
semi conductive cable break-out. Common earthling system. Cable lugs not included.
ELCOTERM TEC --56/E
Heat shrinkable medium voltage outdoor termination either for three core - lead sheathed - individual screen - radial electric field- paper insulated cable (max 36 kV), or for three core - lead sheathed and belted- non radial electric field - paper insulated cable (max 17.5 kV). Cables
armored or not armored. Copper or aluminum conductors. Provided with
semi conductive cable break-out. Common earthling
system. Cable lugs not included.
|